SURE
MEASUREMENTS
- From -1 … + 1000 bar
- From -1 … +1 mbar and from -10 … +10 mbar
- Using high accuracy reference standards (Dead Weigh Tester, DWT) and working standards (Standard electronic pressure gauges and pressure controllers)
- With accuracy ranging from 0.008 % … 0.025 %
- Pursuant to the guidelines DIN EN 837, DAkkS-DKD-R 6-1, EURAMET cg-3 or EURAMET cg-17
- All instruments measuring negative and positive pressure, differential pressure-including the differential pressure under static pressure and absolute pressure
- Analogue pressure gauges
- Electrical pressure transmitters and pressure sensors
- Analogue differential pressure gauges
- Pressure switches
- Meters of fluid column / U-tube pressure gauges
- Inclined pressure gauges
- Pressure calibrators
- Pressure controllers
- Pressure recording instruments
- Absolute and barometric pressure gauges
- Differential pressure sensors
ATURE
MEASUREMENTS
- Ranging from -40 … +1000 °C
- Ranging from -40 … +250 °C (chambers)
- In calibration baths, dry block calibrators and environmental chambers, using the most appropriate standard thermometers
- With accuracy from 5 mK … 1.5 K
- In accordance with the guidelines DKD/DAkkS and EURAMET
- Temperature sensors with transmitters
- Thermoresistances (Pt100, Pt1000 etc.))
- Thermocouples (type ‘K’, ‘J’ etc.)
- Temperature readers, hand-held gauges, temperature recording devices etc
- Different types of sensors such as immersion sensors, surface sensors and air temperature measurement sensors
- Test thermometers
- Mechanical thermometers
- Dry block calibrators
- Temperature calibrators
- Optical thermometers
- Calibration baths
- Incubation cabinets
- Sterilization chambers
- Environmental chambers
DITY
MEASUREMENTS
- From 15 … 95 % Rh
- In environmental chambers of changing conditions, fixed and portable
- With accuracy ranging from 1 … 1.8 %
- In accordance with guidelines DKD/DAkkS and EURAMET
- Humidity sensors with transmitters
- Humidity readers, hand-held gauges, humidity recording devices etc
- Hair-tension humidity meters
- Mechanical humidity meters
ITIES
OTHER QUANTITIES
- Direct Current in the range of 0… 50 mA
- DC voltage in the range of 0 … 20 V
- DC resistance in the range of 0 … 10 kΩ
- Vernier calipers-digital/Micrometers/Metal sheet thickness in the range of 0,5 … 1000 mm
- Rulers/Measuring tapes in the range of
- Paint thickness gauge in the range of 12,5 … 500 μm
ATIONS
YOUR PREMISES
To achieve the minimum possible impact on your manufacturing process and to save time, we offer you on-site calibrations – and by accredited methods in accordance with DIN EN ISO / IEC 17025 – anywhere in Greece, for measuring the levels of pressure, temperature and humidity.
- In pressure ranging from -0,95 … +1000 bar With accuracy from 0,025 % up to 0,3 % F.S.
- In temperature ranging from -30 … +650 °C with accuracy from 0,08 … 1,5 Κ
- In humidity from 15 … 95 % rH With accuracy ranging from 1,0 … 1,8 % rH
ICATES
CERTIFICATES
The calibration complies with the guidelines in force. The measurement results are documented in a calibration certificate and the calibrated meter is labeled with a calibration mark. Depending on your demands, you may opt for either a calibration by an accredited method or a calibration equivalent to the factory calibration.